KLD Mono&Multiple Water Quality Analyzer

Multi-Parametric Water Quality Analyzer

Author: From: Date:2017-6-5 14:22:40 Hits:138

    KLD-C MPA (COD, TOC, BOD, PO4, NH3-N, SiO3 & optional EC/PH/ORP/TS/SS/DO) is an automatic on-line analyzer independently developed by Xiamen Kelungde Env. Engineering Co.,Ltd. Using imported CPU, highly precise signal processor and simple but steady hydraulic system to effectively reduce signal fluctuation and to ensure the accuracy and stability of data. Complete separation between electronics and hydraulics allows long-term & stable running. It is suitable for several types of water matrix like river water, surface water and industrial effluent.

aaa.jpg

Features

1.Robust & Reliable

    Designed for on-line industrial and environmental applications. Complete separation between electronics and hydraulics allows long-term stable operations.

2.Precise Reagent Dosage

    CPU controlled photoelectric dosing system for accurate reagent dosage. Simple & steady structure ensures long-term service life.

3.Easy Installation

    Delivered after a long & successful series of factory tests, it is ready for installation and setup. To start monitoring just need to connect reagent tubes, sample tube, water tube, waste tube and power supply, then set up the parameters.

4.Automatic Calibration

    The analyzer performs calibration according to the calibration interval and type set up by users. If the result exceeds selected limits, the original calibration parameters will not be updated and an alarm signal will be outputted.

5.Automatic Monitoring

    Measuring interval can be freely set up by users. Between two measurements the analyzer remains in standby.


Benefits

?  Automatic monitoring system gives alarm signal in abnormal condition. Easy and low maintenance; Low operating cost.

?  4-20mA analog signal output; standard RS232, RS485 digital signal output, MODBUS protocol.

?  New signal processor reduces signal fluctuation to ensure the accuracy and stability of data.

?  Highly precise peristaltic pump extends the service life of pump tubes.

?  Automatic restart when normal power supply after accidental power down.

?  Remote control with local or remote PC connection.

?  Low reagent consumption; short preparation time.

?  Automatic diagnosis function. Identification and alarm for reagent shortage.

?  Instrument operating signal output function.

?  10000 groups of data storage and USB download for analysis data and running log.

?  Easy operation, no special training is required.

?  Controllable running of water pump and free setup for the sampling time of the pump.

?  Security management function, automatic record and storage for all control operations. Read-only storage.

?  2-level operation & management authorization: The system administrator can have all system operation and general operators can only perform routine maintenance & operation.

?  APP availble for the control of the analyzer. It can be used on the mobile devices using Android operating system, allowing to accomplish following tasks: reverse control of the instrument; read real-time param. & data; upload & view data; sign in with pic.; record the real-time latitude & longitude of sign in; automatic generation of operation & maintenance records.


Optional Function

    Dual-channel 

    One analyzer to monitor on-line for 2 outlets.

    Reagent Cooling

    Longer reagent service life and less reagent replacing.

    Alarm Function

    DI water low limit alarm and waste liquid high limit alarm function.

    Automatic Dilution Function

    Automatic dilution function for high concentration sample.

    Mini Printer

    Print data after measurement.


Measuring Principle

TOC&COD&BOD (UV Method)

    According to the ultraviolet light absorption effect of unsaturated organic molecules at particular wavelength , and then calculated by law of Lambert-Beer. Usually a sample is a mixture of many different molecules to form an average absorption coefficient. The instrument must be calibrated by using laboratory-calibrated TOC/COD/BOD values before use. Also, the proportions of the different molecules should be kept approximately constant to ensure good TOC/COD/BOD correlation. SAC UV absorption method is fast, reliable, low input & maintenance.

Phosphat

    The sample after proper filtration is pumped into reactor, where molybdate is injected to form phosphorus-molybdenum heteropoly acid. Then to inject ascorbic acid into the sample. After fully mixing and reaction, the analyzer measures ABS value of blue substances produced by reaction at the specific wavelength, then calculates sample concentration according to the stored calibration data.

Silicate

    The sample after proper filtration is pumped into reactor, where molybdate is injected to form silico-molybdic heteropoly acid. Then to inject oxalic acid and 4-Methylaminophenol sulfate-sodium sulfite solution into the sample. Oxalic acid is used to minimize the phosphate interference. After fully mixing and reaction, the analyzer measures ABS value of blue substances produced by reaction at 810nm, then calculates sample concentration according to the stored calibration data.

Ammonia (Gas Sensoring Electrode Method)

    The sample after proper filtration is pumped into reactor, Inject reagent to adjust PH value over 12, which will convert all ammonium ion into ammonia which penetrates through electrode membrane. The variation of electrode potential and ammonia value changed in logarithm relation and then calculate the sample concentration.


Specification

Measuring Principle

TOC&COD&BOD: UV Method     PO4/SiO3: Colorimetry    NH3-N: Electrode Method

Operating Management

Security management and 2-level operation management function

Measuring Type

Manual or automatic with interval

Measuring Interval

Programmable; reverse control available by RS232

Measuring Time

TOC&COD&BOD: 9 min      PO4/SiO3/NH3-N:   10 min 

Measuring Range

Ranges available on request

Calibration Type

Manual or automatic with interval

Precision

≤ 3%

Accuracy

±3%

Zero Drift

3%F.S

Range Drift

3%F.S

Signal Output

Standard 4-20mA analog output,

Standard RS232/RS485 digital output, MODBUS Protocol

Alarm

High limit alarm, low limit alarm, reagent shortage alarm,   calibration error alarm (standard)

Sample and Waste Delivery

Pressure free

Reagent Temperature

10-30°C

Reagent Replacement

3~4 weeks (depending on the ambient temperature)

Ambient temperature

5-40°C

Protection

IP55

MTBF

720h

Display

Color touch screen (language: Chinese Simplified, Chinese   Traditional, English)

Power supply

230V AC±10%; 50-60 Hz

Weight

20 kg (without reagents)

Dimension

600x400x300mm(H x W x D)


    Tags:KLD-C MPA